For homeowners, builders, and property owners in designated bushfire prone areas, a Bushfire Attack Level (BAL) rating is one of the most important numbers on a project. It identifies a building’s potential exposure to ember attack, radiant heat, and direct flame contact, and it shapes the materials and protective measures the build requires.
There are six BAL levels, from BAL-Low to BAL-FZ. Below, we explain how a BAL assessment works, what each level means for construction, and where correctly specified bushfire mesh fits in.
TL;DR
- A BAL rating measures a building’s potential exposure to ember attack, radiant heat, and direct flame contact.
- There are six levels under AS 3959: BAL-Low, BAL-12.5, BAL-19, BAL-29, BAL-40, and BAL-FZ.
- Your BAL is set by a site-specific assessment of fire danger index, vegetation, distance, and slope.
- A higher BAL means stricter requirements for roofs, walls, windows, doors, vents, and subfloors.
- Ember screening generally needs a maximum 2 mm aperture, with permitted materials narrowing as the BAL rises.
- Stainless steel bushfire mesh can help restrict ember entry, but compliance depends on the complete installation, not the mesh alone.
What is a BAL rating in Australia?
A BAL rating, sometimes called a bushfire hazard rating, describes the severity of a building’s potential exposure to bushfire attack. It is set out in Australian Standard AS 3959:2018 (incorporating Amendments 1 and 2), Construction of buildings in bushfire-prone areas, which the National Construction Code (NCC) references for buildings located in designated bushfire prone areas.
A BAL assessment considers three forms of exposure:
- Ember attack: burning embers and debris carried by wind, which can lodge in gaps or enter openings well ahead of the fire front.
- Radiant heat: heat energy radiating from the fire, measured in kilowatts per square metre (kW/m²).
- Direct flame contact: flames reaching the building itself.
Your rating determines the specific construction requirements for a new residential building or other building work. It is not a prediction that a bushfire will occur, nor a guarantee of how a building will perform.
What are the six bushfire attack levels?
AS 3959 defines six BAL levels, each reflecting increasing levels of radiant heat (heat flux) and the likelihood of flame contact.
| BAL rating | Potential bushfire exposure | General construction implications |
| BAL-Low | Very low risk; insufficient to warrant specific construction requirements | Generally no specific AS 3959 bushfire construction requirements |
| BAL-12.5 | Low risk; ember attack and radiant heat up to 12.5 kW/m² | Entry-level measures to resist ember entry |
| BAL-19 | Risk considered moderate; increasing ember attack and burning debris ignited by windborne embers, with radiant heat above 12.5 up to 19 kW/m² | Additional protection of vulnerable building elements |
| BAL-29 | High risk; ember attack and radiant heat above 19 up to 29 kW/m² | More demanding material and construction requirements |
| BAL-40 | Very high risk; ember attack, increased likelihood of flame contact, and radiant heat above 29 up to 40 kW/m² | Higher levels of bushfire-resistant construction |
| BAL-FZ | Extreme risk; direct exposure to flames from the fire front, plus ember attack and radiant heat above 40 kW/m² | The most demanding bushfire construction classification |
The number in each rating is the radiant heat threshold in kW/m². Exact requirements depend on the building type and any state or territory variations.
How is a bushfire attack level determined?
A BAL assessment is a site-specific evaluation of the building site. AS 3959 sets out two methods, a simplified procedure (Method 1) and a detailed procedure (Method 2). Both start with the regional fire danger index (FDI) before looking at the site itself.
Surrounding vegetation
The assessor classifies the vegetation within 100 metres of the site, such as forest, woodland, shrubland, or grassland, because each type carries a different fuel load.
Distance from vegetation
Greater separation between the building and classified vegetation generally means lower radiant heat exposure.
Slope of the land
Effective slope is the slope of the land under the vegetation. Fire travels faster uphill, so a home sitting above downslope bushland can face higher exposure.
Building location and site conditions
The proposed building position, managed land around it, and any jurisdictional requirements also shape the result.
Because this is a calculated process, not a guess based on nearby trees, engaging a qualified bushfire practitioner is recommended.
How can you find out your property’s BAL rating?
First, check whether official mapping identifies land at your address as bushfire prone. In Victoria, VicPlan shows bushfire prone areas and the Bushfire Management Overlay (BMO). Western Australia publishes a Map of Bush Fire Prone Areas, and elsewhere your local council can confirm whether its mapping or the council’s planning scheme applies.
Check existing building documentation
Review approved plans, any earlier BAL assessment reports, and bushfire conditions on a planning permit.
Contact your local council or relevant authority
Your council can confirm the bushfire mapping and the planning and building requirements that apply to your property.
Arrange a professional BAL assessment
For new buildings in bushfire prone areas, a BAL assessment typically forms part of the building permit application. Your private building surveyor or building certifier can confirm what documentation is needed.
Confirm requirements before construction
Make sure the assessment matches your proposed design and siting. Changes to development plans or surrounding vegetation may require reassessment.
Being mapped as bushfire prone does not, by itself, establish a particular BAL.
What does BAL-12.5 mean for your home?
BAL-12.5 covers ember attack and radiant heat up to 12.5 kW/m². Requirements focus on sealing gaps, screening specified openings such as openable windows, vents, and weep holes, and using suitable materials for exposed elements. Even at this level, ember exposure is significant.
What are the requirements for BAL-19 and BAL-29?
BAL-19
Exposure increases compared with BAL-12.5, so construction details become more demanding and material restrictions extend to more building elements.
BAL-29
Radiant heat exposure is higher again, with greater attention to external walls, glazing, doors, vents, and roof-related openings.
What does this mean for ember mesh?
Ember screens at these levels may generally be corrosion-resistant steel, bronze, or aluminium, but not every aluminium screen is suitable. Some state variations, such as South Australia’s provisions in the NCC, restrict aluminium screening for certain applications, so always check local requirements.
What do BAL-40 and BAL-FZ mean?
BAL-40
BAL-40 brings substantial radiant heat and an increased likelihood of flame contact. Many elements must be non-combustible or part of a tested system, and permitted screening narrows to corrosion-resistant steel or bronze.
BAL-FZ (flame zone)
The highest classification, with potential direct flame contact. Windows, doors, and other assemblies may need to be specifically designed or tested.
Why material selection matters
Screens, frames, fixings, and surrounding construction all affect compliance. Fine stainless steel mesh alone does not make a window, vent, or building BAL-FZ compliant, so professional design advice is essential.
How does your BAL rating affect building materials?
A higher BAL rating means stricter material requirements across the building envelope.
Roofing materials
Roof coverings must be non-combustible, with junctions, penetrations, and gaps sealed against embers.
External walls
At higher levels, cladding and wall construction increasingly need to be non-combustible or otherwise compliant, including at junctions.
Windows and doors
Glazing, frames, seals, and any screens or shutters must suit the BAL.
Decks and subfloors
Decking materials, supporting components, and subfloor openings all need appropriate protection.
Vents and weep holes
Compliant ember screening must still allow drainage and ventilation. Non-combustible gutters and guards also help stop leaf litter igniting.
Compliance comes from the complete design and construction system, not a single product.
What are the BAL mesh requirements in Australia?
Maximum mesh aperture size
Where AS 3959 calls for ember screening, it generally specifies mesh or perforated sheet with a maximum aperture of 2mm. The aperture is the opening between the wires, not the wire thickness or the mesh count.
Acceptable mesh materials
Corrosion-resistant steel and bronze are accepted wherever screening applies, while aluminium is generally limited to BAL-12.5 to BAL-29. Ordinary fibreglass flyscreen is not a substitute for compliant ember screening.
Installation requirements
Mesh must also be securely fixed, with gaps around the screen kept within AS 3959 limits, suitable frames and fixings, and ventilation and drainage maintained. Requirements tighten as the BAL increases.
Why is stainless steel mesh used for bushfire protection?
Stainless steel is non-combustible, strong, and corrosion-resistant, and fine woven stainless mesh can achieve apertures well under 2mm while preserving airflow and visibility.
- 304 stainless steel suits most general outdoor environments.
- 316 stainless steel offers enhanced corrosion resistance for coastal or high-chloride environments.
Learn more in our guide, Should you use 304 or 316 stainless steel? No mesh provides complete fire protection on its own.
Where can bushfire mesh be installed around a property?
Subject to your BAL and the applicable construction requirements, common applications include:
- Openable windows and sliding doors
- Roof vents, gable openings, and eaves
- Subfloor areas, where permitted for your BAL
- Weep holes, without obstructing drainage
- Deck enclosures and outdoor structures
In every case, the complete window, door, or opening assembly must meet the relevant requirements.
Can you improve bushfire protection on an existing home?
Yes, and it is worth investigating even if you are not undertaking a full building upgrade.
Review vulnerable openings
Reducing bushfire risk starts with inspecting vents, gaps, and other potential ember entry points.
Assess existing screening
Check the mesh material and aperture size, and look for damaged sections, frames, or fixings.
Consider suitable retrofit measures
Install appropriately specified ember screening where applicable, repair gaps, and keep roofs and gutters clear of leaf litter.
Seek professional advice
Confirm that proposed changes meet applicable requirements, and avoid assuming a retrofit brings your whole home to a particular BAL.
Common misunderstandings about BAL ratings
“My property has a BAL rating, so it will be safe during a bushfire”
A BAL rating describes assessed exposure and informs construction requirements. It is not a safety guarantee.
“All metal mesh is BAL compliant”
Material, aperture, installation, and building application all matter.
“A 2 mm mesh opening is the only requirement”
Aperture size alone does not establish compliance.
“BAL requirements are the same across Australia”
National standards sit alongside each state’s building act, building regulations, and planning rules.
“Installing bushfire mesh makes my home bushfire-proof”
Ember screening is one part of a broader bushfire safety strategy.
“My BAL rating never changes”
Changes to vegetation, siting, or development can require reassessment.
How do you choose the right bushfire mesh for your BAL rating?
- Confirm your BAL and identify the opening being screened.
- Check which materials are permitted for that BAL and building element.
- Verify the product’s actual aperture and wire specifications.
- Choose a 304 or 316 grade to suit the environment.
- Confirm frames, fixings, and installation suit the complete system, seeking advice where required.
Stainless steel bushfire mesh from Stainless Mesh Australia
Stainless Mesh Australia supplies stainless steel bushfire mesh to builders, fabricators, and homeowners, with:
- 304 and 316 grade options
- Apertures of approximately 1.5 – 1.67 mm
- Wire diameters from 0.45 mm to 0.9 mm, in rolls and sheets
- Mill and black powder-coated finishes
- Trade and retail supply with nationwide delivery
Product selection and installation should always be checked against your BAL and project requirements.
Know your BAL before you build
Understanding your BAL rating is essential when building or renovating in bushfire prone areas. Your rating, from BAL-Low to BAL-FZ, shapes materials, construction details, and the protection of vulnerable openings. Properly specified stainless steel mesh can contribute to ember protection as part of the complete building system, so confirm your BAL assessment and seek professional advice before selecting materials.
Looking for stainless steel bushfire mesh for your building or renovation project? Explore our range of 304 and 316 stainless steel bushfire mesh or contact our team to discuss the specifications required for your application.

Recent Posts

Understanding Your Bushfire Attack Level (BAL) Rating in Australia

Understanding Your Bushfire Attack Level (BAL) Rating in Australia

The Hidden Problem Under Solar Panels Most Homeowners Don’t Notice Until It’s Too Late

DIY Spotlight: 5 Creative Home Projects Using Stainless Steel Mesh